Setting Register Mark Detection Conditions
- Press the [FUNCTION] key in local mode.
- Press the keys to select [SET UP], then press the [ENTER/HOLD] key.
- [MARK DETECT] appears on the screen.
- Press the [ENTER/HOLD] key.
- [MARKDETECT: OFF] appears on the screen.
- Press the keys to select the number of register marks to be detected, then press the [ENTER/HOLD] key.
- Settings: OFF, 1pt, 1ptA, 2ptB, 3pt, 4pt
- Register mark detection is not performed when "OFF" is selected. Press the [END] key several times to exit.
- Pressing the [ENTER/HOLD] key toggles through the following items on the display. Use the keys to select the setting, then press the [ENTER/HOLD] key.
- Scale compensation/Register mark size/Offset A/Offset B/Form of registration mark/Number of continuous cutting in direction A/Number of continuous cutting in direction B/High-speed limit/Skew check/Detect mode/Sensor sensitivity/Filled in register marks/Data ID code
Notes on Register Mark Detection Setting Items
- Press the [END] key several times to exit.